DC Voltage |
420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±2 dgt. |
AC Voltage /50 to 500 Hz |
420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt., (Average rectified) |
|
Resistance |
420.0 Ω to 42.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±2 dgt. |
DC Current |
42.00 μA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±1.5 % rdg. ±4 dgt. |
AC Current /50 to 500 Hz |
42.00 μA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±2.5 % rdg. ±5 dgt., (Average rectified) |
|
Hz (Frequency) |
199.99 Hz to 500.0 kHz, 5 ranges, Basic accuracy: ±0.02 % rdg. ±1 dgt., Input level: 0.8 V to 1000 V, 4 levels, Frequencies of less than 0.50 Hz cannot be measured |
Duty ratio measure |
Not available |
|
Voltage Detection |
Bring the top close to the power line, when the voltage is outside of the detection range, buzzer and the display blinks |
Not available |
Continuity buzzer |
Threshold 50 Ω ± 40 Ω, Open terminal voltage: 3.4 V or less |
Diode check |
Open terminal voltage: 3.4 V or less, Testing current: 700 μA |
Other function |
Relative value, Memory, Auto power save, Auto hold, Recoding (Max./ Min. / Ave.) |
Display |
Digital/ LCD, max. 4200 digits (19999 digits at frequency measure) |
Sample rate |
2.5 times/s (except Frequency), 5 times/s (Frequency, over 5 Hz), 25 times/s (Update of bar graph) |
Power supply |
Manganese battery (R03) ×2, Continuous use: 100 hours |
Dimensions and mass |
76W (2.99in) × 167H (6.57in) × 33D (1.30in) mm, 260 g (9.2 oz) |
Supplied accessories |
TEST LEAD×1, Instruction Manual×1, Manganese batteries(R03)×2 (for trial purposes only), CARRYING CASE 9378× |