Frequency Accuracy:2.5 ppm typical25 ppm 0° to 50° C, at 50/60 Hz MaximumAC/DC AUX: 250 ppm, 50/60 Hz Maximum
Measured output quantities such as AC Amperes, AC Volts, DC Volts or DC Amperes, and Time may be simultaneously displayed on the touch screen. Preset AC and DC outputs display the approximate voltage/current output prior to initiation. This provides a fast, easy method for preset of outputs. Other values that may be displayed, depending on which test screen is in view, are phase angle, frequency, Ohms, Watts, VA, and Power Factor. All Accuracies stated are from 10 to 100% of the range at 50/60 Hz.
AC Voltage Amplitude
Accuracy: ±0.05 % reading + 0.02 % range typical,±0.15 % reading + 0.05 % range maximum
Resolution: .01
Measurements: AC RMS
Ranges: 30, 150, 300V
AC Current Amplitude
Accuracy: ±0.05 % reading + 0.02 % range typical,±0.15 % reading + 0.05 % range maximum
Resolution: .001/.01
Measurements: AC RMS
Ranges: 32, 60A
DC Voltage Amplitude
Accuracy: 0.1% range typical,0.25% range maximum
Resolution: .01
Measurements: RMS
Ranges: 30, 150, 300V
DC Current Amplitude
Accuracy: ±0.05 % reading + 0.02 % range typical,±0.15 % reading + 0.05 % range maximum
Resolution: .001/.01
Measurements: RMS
Ranges: 32A
AC/DC AUX Voltage Channel
AC Accuracy: ±0.05 % reading + 0.02 % range typical,±0.15 % reading + 0.05 % range DC Accuracy: 0.1% range typical, 0.25% range maximum
Resolution: .01
Measurements: RMS
Range: 30, 150 AC/DC, 250 DC