Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)*1 Your instrument can be used to measure voltages in excess of 1000 V DC if and only if both of the following conditions are satisfied: 1. The circuit under measurement is isolated from the commercial power grid. 2. The circuit under measurement is isolated from ground.
|
DC Current range
|
20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
|
AC Current range
|
20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±0.08 A (at 20 A)
|
Crest factor
|
20.00 A range: 7.5
600.0 A range: 3 or less
|
DC+AC Current range
|
20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
|
DC Voltage range
|
600.0 mV to 1500 V (*1), 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
|
AC Voltage range
|
6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.013 V (at 6 V)
|
DC+AC Voltage range
|
6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.023 V (at 6 V)
|
Resistance range
|
600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
|
Capacitance range
|
1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
|
Frequency range
|
9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
|
Temperature (K)
|
-40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
|
Voltage detection
|
Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
|
Other functions
|
Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment
|
Dustproof, waterproof
|
Grip: IP54 (when measuring an insulated conductor only), Jaw (the current sensor portion of the instrument)/ barrier: IP50 *Risk of electric shock from the conductor being measured increases when wet.
|
Power supply
|
LR03 Alkaline battery ×2, Continuous use 45 hr (Backlight OFF)
|
Core jaw diameter
|
φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in) D
|
Dimensions and mass
|
65 mm (2.56 in) W × 215 mm (8.46 in) H × 35 mm (1.38 in) D mm, 340 g (12.0 oz)
|
Accessories
|
TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual×1
|